Investigation of factors affecting hypothermic pelvic tissue cooling using bio-heat simulation based on MRI-segmented anatomic models

Abstract

© 2015 Elsevier Ireland Ltd.This study applied a simulation method to map the temperature distribution based on magnetic resonance imaging of individual patients, and investigated the influence of different pelvic tissue types as well as the choice of thermal property parameters on the efficiency of endorectal cooling balloon. MR images of four subjects with different prostate sizes and pelvic tissue compositions, including fatty tissue and venous plexus, were analyzed. The MR images acquired using endorectal coil provided a realistic geometry of deformed prostate that resembled the anatomy in the presence of ECB. A single slice with the largest two-dimensional cross-sectional area of the prostate gland was selected for analysis. The rectal wall, prostate gland, peri-rectal fatty tissue, peri-prostatic fatty tissue, peri-prostatic venous plexus, and urinary bladder were manually segmented. Pennes' bioheat thermal model was used to simulate the temperature distribution dynamics, by using an in-house finite element mesh based solver written in MATLAB. The results showed that prostate size and periprostatic venous plexus were two major factors affecting ECB cooling efficiency. For cases with negligible amount of venous plexus and small prostate, the average temperature in the prostate and neurovascular bundles could be cooled down to 25. °C within 30. min. For cases with abundant venous plexus and large prostate, the temperature could not reach 25. °C at the end of 3. h cooling. Large prostate made the cooling difficult to propagate through. The impact of fatty tissue on cooling effect was small. The filling of bladder with warm urine during the ECB cooling procedure did not affect the temperature in the prostate or NVB. In addition to the 2D simulation, in one case a 3D pelvic model was constructed for volumetric simulation. It was found that the 2D slice with the largest cross-sectional area of prostate had the most abundant venous plexus, and was the most difficult slice to cool, thus it may provide a conservative prediction of the cooling effect. This feasibility study demonstrated that the simulation tool could potentially be used for adjusting the setting of ECB for individual patients during hypothermic radical prostatectomy. Further studies using MR thermometry are required to validate the in silico results obtained using simulation.

Other Versions

No versions found

Links

PhilArchive



    Upload a copy of this work     Papers currently archived: 101,667

External links

Setup an account with your affiliations in order to access resources via your University's proxy server

Through your library

  • Only published works are available at libraries.

Similar books and articles

Efficiency Cooling Channel at Core Side Incorporating with Baffle and Bubbler System.Saiful Bahri Mohd Yasin, Noor Faezah Mohd Sani, Salwa Adnan, Zahidahthorwazunah Zulkifli, Zuliahani Ahmad & Sharifah Nafisah Syed Ismail - 2018 - Proceedings of the Second International Conference on the Future of Asean (Icofa) 2017 – Volume 2: Science and Technology:515-522.

Analytics

Added to PP
2017-05-17

Downloads
5 (#1,754,736)

6 months
2 (#1,690,857)

Historical graph of downloads
How can I increase my downloads?

Author Profiles

Ya-Ping Lin
National Taiwan University
Weili Lin
National Taiwan University

Citations of this work

No citations found.

Add more citations

References found in this work

No references found.

Add more references